Testing for a Better Life
EQUIPMENT
CLIMATIC CHAMBER
For the simulation of controlled conditions in temperature and relative humidity.
Capacities:
Temperature: -70 ̊C to 180 ̊C
Humidity: 10% RH to 95% RH
Dimensions :
60 cm x 60 cm x 60 cm
97 cm x 97 cm x 97 cm
Standards:
PV 1200;
IEC 60068-2-30 ;
TS 956 Sec. 6.7,6.39;
TSC 1224G Sec. 6.2.1, 6.2.2, 6.2.4, 6.2.8;
GMW 3172,
GMW 14444;
ISO 16750 4 Sec. 6.2.1, 6.2.2, 6.2.4, 6.2.8;
NES M 0132;
USCAR-21 Sec.4.5.4
VIBRATION SYSTEM
Equipment that simulates vibrations for the analysis of materials in components, parts, systems, etc.
Capacities:
Sinusoidal Resonance
Random
Shock
Frequency: 2.5 Hz to 2,500 Hz
Displacement: 51mm
Force: 10kN
Maximum Speed: 2 m / s
Maximum Acceleration: 100 G
Temperature Range: -70 ̊C to 180 ̊C
Standards:
IEC 60068-2-6,
IEC 60068-2 -27,
IEC 60068-2-64;
GMW3172
TN 956 Sec. 6.5;
V W 80 200
PF -12742 Sec.3.4.1.1, 3.4.2, 3.4.3
CORROSION CHAMBER
Simulates a salty environment to check the corrosion resistance of materials.
Capacities:
Sodium Chloride: 5%
Humidity: 100%
RH Temperature: 38 ̊ C to 50 ̊ C
Dimensions:
90 cm x 60 cm x 50 cm
Standards:
ASTM B117-16
ISO 9227: 2017-03
NES 0007 Sec. 33
TS1229G, Sec. 5.2.3
ELECTRICAL
They simulate the electrical operating conditions of the sample.
AC / DC power sources
Voltage: 0 V to 310 V
Current: 10 A to 20 A
Resolution: 0.1 V
DC power sources
Current: 0 A to 80 A
Voltage: 0 V to 160 V
Power: 12 kW
Multimeter High resolution
Resolution: 6½ digits
Battery power sources:
Voltage: 15 V Current: 30 A
DATA ACQUISITION SYSTEMS
Acquisition equipment for multiple sensors that validate the reliability of the results.
Analog inputs: 24 bits
Sampling rate: 200 kS / s - 1 MS / s
Dynamic range: 160 dB
Digital outputs: 12 VDC, 24VDC and 36 VDC
Isolated channels: 1kV galvanic isolation
Counter inputs
DUST CHAMBER
They are designed to simulate dust-flooded environments in which different materials are exposed for a certain time.
Capacities:
0 s to 120 s
0 psi to 150 psi
Standards:
FMVSS 108
SAE J575
TL 956
RAIN SIMULATION
Designed for testing materials or products that will be exposed to the elements, this system can be controlled in pressure, height, type of drop and speed of waterfall.
Dimensions :
2.80 m x 3.90 m x 4 m
Standard:
IEC 60068-2-18
MECHANICAL SHOCK
Vibration Mechanism 0.125 in ± 0.016 in Speed: 750 ± 25 cpm
Dimensions:
7.9 in x 11 in
Standard:
FMVS 108
THERMAL SHOCK
The thermal shock test consists of subjecting a component to sudden changes in temperature, this is a chieved by using two chambers that are at controlled temperatures to generate thermal stress.
Capacities:
Temperature: -60 °C to +150 °C
Max weigth: 25 Kg
Dimensions:
48cm x 48 cm x 48 cm